Introduction Dental implants are the treatment of choice for patients, who are either partially or fully edentulous. Bone quantity and quality at the surgical site are key factors in an implant success. Objectives To investigate the possibility of performing density measurement with Hounsfield units (HU) using cone-beam computed tomography (CBCT) in different types of materials. Material and methods The physical densities of 3 blocks (3 × 3 × 5 cm) made of 5 different materials (pine, beech, plaster, acrylic, and wax) were calculated. A VistaVoxS 3D CBCT device was used to scan each block using the following acquisition protocol: 5 × 5 field-of-view, 98 kVp, 11 mAs, and 0.08 voxel size. The resulting 15 CBCT scans after acquisitions were imported to AIS3DAPP 5.0 software. A virtual implant (16 mm × 5.2 mm) was centered in each block’s image, and bone density tool available in the software was used to measure HU with the virtual implant’s thirds. For each implant, mean HU values of the most anterior, posterior, left, and right sides were measured. Results In general, each material produced different mean HU values. Plaster produced the highest values (2,160.9), followed by acrylic (126.39), wax (–170.65), beech (–655.78), and pine (90.12) Conclusions CBCT HU were repeatable and higher in the high-density material studied. The bone density tool demonstrated to be useful and reproducible. keywords: bone density, cone-beam computed tomography, grey values
Open Access
Linki zewnętrzne
Identyfikatory
Metryki
Eksport cytowania
Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.
Punkty i sloty autorów
| Autor | Dyscyplina | PkD / PkDAut | Slot |
|---|---|---|---|
| Kalinowski Paweł, dr hab. n. med. | nauki o zdrowiu | 20,0000 | 0,5000 |
| Różyło-Kalinowska Ingrid, prof. dr hab. n. med. | nauki medyczne | 20,0000 | 0,5000 |
Punkty i sloty dyscyplin
| Dyscyplina | PkD / PkDAut | Slot |
|---|---|---|
| nauki medyczne | 20,0000 | 0,5000 |
| nauki o zdrowiu | 20,0000 | 0,5000 |
Informacje dodatkowe
| Zewnętrzna baza danych: | • Scopus |
|---|---|
| Rekord utworzony: | 22 września 2023 12:42 |
| Ostatnia aktualizacja: | 20 października 2025 09:40 |