Patient-clustered analysis of recorded insertion torque in 101 multineo titanium dental implant placements: an exploratory retrospective cohort study. [AUT. KORESP.] KATARZYNA WIECZOREK, [AUT.] ADRIAN WASILEWSKI, BARTŁOMIEJ SZWED, WERONIKA NICPOŃ, NATALIA SZYMKOWIAK, GRZEGORZ HAJDUK, MANSUR RAHNAMA-HEZAVAH, MICHAŁ ŁOBACZ. Materials [online] 2026 vol. 19 nr 16 [art. nr] 3560, s. 1-13, bibliogr. poz. 36, [przeglądany 26 sierpnia 2026]. Dostępny w: https://www.mdpi.com/1996-1944/19/16/3560. DOI: 10.3390/ma19163560
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Źródło:
Materials [online] 2026 vol. 19 nr 16, [art. nr] 3560, s. 1-13, bibliogr. poz. 36.
Rok:2026
Język:angielski
Charakter formalny:Artykuł w czasopiśmie
Typ MNiSW/MEiN:Praca Oryginalna

Streszczenia

Abstract Primary implant stability arises from mechanical engagement at placement, and insertion torque is not a direct measure of osseointegration. This retrospective single-centre study included 101 MultiNeO titanium implant placements in 55 adults treated between April 2023 and January 2026. Four experienced operators placed implants subcrestally using a W&H Implantmed SI-1023, a bone-resistance-adapted drilling protocol, and a programmed target of 35 N·cm. Associations with recorded torque were assessed using a patient-clustered Gaussian generalized estimating equation adjusted for sex, age, anatomical sector, implant length and diameter, hard-tissue augmentation, and placement timing. The mean torque was 31.63 ± 5.57 N·cm; the median was 35 N·cm (Q1–Q3, 30–35). Recorded torque was 3.25 N·cm higher for implants placed in women than for those placed in men (95% CI 1.20–5.31; p = 0.002). Relative to maxillary anterior/premolar sites, mandibular molar sites showed higher torque (β = 4.02; p = 0.001), whereas mandibular anterior/premolar sites showed lower torque (β = −5.41; p = 0.013). Implant length had a modest adjusted association (β = 0.93 N·cm/mm; p = 0.022); age, diameter, augmentation, and placement timing did not. The concentration of recorded values at 35 N·cm reflects a clinical target rather than the device limit. These exploratory associations do not establish an intrinsic sex effect or predict osseointegration, and residual confounding due to unmeasured bone characteristics remains possible. Keywords: dental implants; insertion torque; primary stability; generalized estimating equations; MultiNeO; titanium alloy; anatomical site; retrospective cohort

Open Access

Tryb dostępu:otwarte czasopismoWersja tekstu:ostateczna wersja opublikowanaLicencja: Creative Commons - Uznanie Autorstwa (CC-BY) Czas udostępnienia:w momencie opublikowania

Identyfikatory

BPP ID: (27, 105280) wydawnictwo ciągłe #105280

Metryki

140,00
Punkty MNiSW/MEiN
3,700
Impact Factor
Q1
SCOPUS
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Rekord utworzony:26 sierpnia 2026 07:49
Ostatnia aktualizacja:26 sierpnia 2026 13:19